Metal Seated Gate Valve

Home > Category > Gate Valve > Metal Seated Gate Valve  > Metal Seated Gate Valve

Main Product

News

The Difference Between A Lug and Wafer Butterfly Valve

The Difference Between A Lug and Wafer Butterfly Valve

2019-02-12 16:59:28

Butterfly valves have been around for a long time, and are used for a variety of applications. They made their first appearance during the 1930s, and have been utilized by several industries ever since. Often made out of cast iron, butterfly valve's name is based from the functionality of its disc.

Wafer type butterfly valve installation instructions and steps

Wafer type butterfly valve installation instructions and steps

2019-01-03 16:27:13

The wafer butterfly valve is one of the most common types of valves in industrial pipelines. The structure of wafer butterfly valve itself is relatively small. It is only necessary to put the butterfly valve in the middle of the flange at both ends of the pipe, and use the stud bolt to pass through the pipe flange and the pair.

Twenty-five Taboos for Valve Installation

Twenty-five Taboos for Valve Installation

2019-09-06 10:23:57

Valves are the most common equipment in chemical companies. It seems easy to install valves, but if they are not implemented in accordance with the re...

Manual valve operation method

Manual valve operation method

2019-04-01 11:50:16

The manual valve is a valve operated by the handle and the hand wheel, and is a commonly used valve on the equipment pipeline.

Valve common standards and differences

Valve common standards and differences

2019-05-07 17:37:21

DIN standard now uses EN standard structure length
EN 558-1 PN flange connection valve construction length (instead of DIN 3202), EN 558-2 CLASS flange connection valve construction length (instead of BS2080), EN 12982 butt weld end valve construction length (instead of DIN 3202), DIN standard The length of the structure including the length of the API valve is basically the same as the length of the GB...

Butterfly Valve Seat & Seal Ring Replacement Method

Butterfly Valve Seat & Seal Ring Replacement Method

2021-02-01 18:14:53

The butterfly valve disc is a key component of the butterfly valve, which acts on closing and opening and closing. Butterfly valve seat and butterfly ...

Resilient Seated Gate Valve

Resilient Seated Gate Valve

2022-10-17 16:09:38

Resilient-seated gate valve with bolted cover connection; made of ductile iron materials and with epoxy coating, designed as both clockwise and anti-c...

What's the working principle of Kieselguhr Filter?

What's the working principle of Kieselguhr Filter?

2019-07-01 13:05:32

What is Kieselguhr Filter? What's the working principle of Kieselguhr Filter? The kieselguhr filter (Candle filter /  Cake Filter) which we for customized for fluorine chemical plant six more lithium fluoride phosphate phosphorus process have been installed and working for two years

New designed PTFE  RPTFE sealing replaceable seat high performance butterfly valve

New designed PTFE RPTFE sealing replaceable seat high performance butterfly valve

2022-04-24 10:39:22

MINOTAUR series replaceable seat high performance butterfly valve

Contact us

RKSfluid Flow Control Company

Web: www.rksfluid.com
Tel:  +86 24 2318 0188
Fax: +86 24 2318 0788
Mail: info@rksfluid.com

Metal Seated Gate Valve

  • Size: DN50 - DN2000
  • Pressure Ratings: PN10, PN16, PN25, PN40
  • Connections: Flange
  • Temperature: ≤ 80°C
  • Body Materials: Ductile iron
  • Medium: Water
  • Design Standard: BS5163/DIN3352
  • Face to Face: BS5163, DIN3202 F4, DIN3202 F5
  • Flange Standard: EN1092-2, ASME B16.10, AS4087
  • Applications: Water supply and water treatment
  • Product Details

RKSfluid Metal-Seated Gate Valves are designed for on-off isolation in water supply and water treatment pipelines. Available in sizes DN50–DN2000 and pressure ratings PN10, PN16, PN25 and PN40, the valves feature a ductile iron body with a ductile iron disc fitted with brass or bronze sealing components.

The metal-seated design provides a metal-to-metal sealing interface for water service. Flanged connections and face-to-face dimensions can be specified according to the applicable product standard and project requirements. 


Looking for a Metal-Seated Gate Valve for Your Project?

Contact RKSfluid with your required valve size, pressure rating, flange standard, face-to-face dimensions and project operating conditions. Our team can help review the specified configuration for your water supply or water treatment application.

*Send us your specifications to request a quotation.


FAQs

Metal-seated gate valves use metallic seating surfaces, such as brass or bronze, while resilient-seated designs use an elastomer-covered wedge. This difference affects the sealing interface and should be considered when selecting a valve for a specific water service.
Check the nominal size, pressure rating, face-to-face length, flange drilling and operating conditions. Matching the connection dimensions is essential when replacing a valve without modifying the pipeline.
F4 and F5 define different face-to-face dimensional series. The required series must match the pipeline layout or specified valve dimensions; they should not be treated as interchangeable.
The nominal pressure rating should be selected against the pipeline design pressure and applicable engineering standard. RKSfluid's listed ratings are PN10, PN16, PN25 and PN40.
The main considerations are water chemistry, corrosion resistance, material compatibility and project specifications. Brass and bronze are available seating-material options for this product range.
Face-to-face dimensions and flange drilling must both match the pipeline specification. Relevant references include BS 5163 or DIN 3202 F4/F5 for dimensional requirements, and EN 1092-2 or AS 4087 for flange requirements, as applicable.
Include size, pressure rating, quantity, design standard, face-to-face dimension, flange drilling, water-service conditions and required material documentation. This helps reduce clarification rounds during technical review.
The listed maximum operating temperature is 80°C. Selection should also account for the specified pressure rating, water conditions and installation requirements.
RKSfluid Flow Control Co., Ltd.

Tel:+86 151 4027 2439

Contact Person:Damon

Damon
Send Us An Inquiry
We will contact you as soon as possible!
Phone
Phone
WeChat
Teams
Whatsapp
captcha