Axial Flow Check Valve Low Pressure Drop Blue Epoxy Coated OEM ODM Customized for Water Pump Discharge

Home > Category > Check Valve  > Axial Flow Check Valve Low Pressure Drop Blue Epoxy Coated OEM ODM Customized for Water Pump Discharge

Main Product

News

The Difference Between A Lug and Wafer Butterfly Valve

The Difference Between A Lug and Wafer Butterfly Valve

2019-02-12 16:59:28

Butterfly valves have been around for a long time, and are used for a variety of applications. They made their first appearance during the 1930s, and have been utilized by several industries ever since. Often made out of cast iron, butterfly valve's name is based from the functionality of its disc.

Wafer type butterfly valve installation instructions and steps

Wafer type butterfly valve installation instructions and steps

2019-01-03 16:27:13

The wafer butterfly valve is one of the most common types of valves in industrial pipelines. The structure of wafer butterfly valve itself is relatively small. It is only necessary to put the butterfly valve in the middle of the flange at both ends of the pipe, and use the stud bolt to pass through the pipe flange and the pair.

Twenty-five Taboos for Valve Installation

Twenty-five Taboos for Valve Installation

2019-09-06 10:23:57

Valves are the most common equipment in chemical companies. It seems easy to install valves, but if they are not implemented in accordance with the re...

Manual valve operation method

Manual valve operation method

2019-04-01 11:50:16

The manual valve is a valve operated by the handle and the hand wheel, and is a commonly used valve on the equipment pipeline.

Valve common standards and differences

Valve common standards and differences

2019-05-07 17:37:21

DIN standard now uses EN standard structure length
EN 558-1 PN flange connection valve construction length (instead of DIN 3202), EN 558-2 CLASS flange connection valve construction length (instead of BS2080), EN 12982 butt weld end valve construction length (instead of DIN 3202), DIN standard The length of the structure including the length of the API valve is basically the same as the length of the GB...

Butterfly Valve Seat & Seal Ring Replacement Method

Butterfly Valve Seat & Seal Ring Replacement Method

2021-02-01 18:14:53

The butterfly valve disc is a key component of the butterfly valve, which acts on closing and opening and closing. Butterfly valve seat and butterfly ...

Resilient Seated Gate Valve

Resilient Seated Gate Valve

2022-10-17 16:09:38

Resilient-seated gate valve with bolted cover connection; made of ductile iron materials and with epoxy coating, designed as both clockwise and anti-c...

What's the working principle of Kieselguhr Filter?

What's the working principle of Kieselguhr Filter?

2019-07-01 13:05:32

What is Kieselguhr Filter? What's the working principle of Kieselguhr Filter? The kieselguhr filter (Candle filter /  Cake Filter) which we for customized for fluorine chemical plant six more lithium fluoride phosphate phosphorus process have been installed and working for two years

New designed PTFE  RPTFE sealing replaceable seat high performance butterfly valve

New designed PTFE RPTFE sealing replaceable seat high performance butterfly valve

2022-04-24 10:39:22

MINOTAUR series replaceable seat high performance butterfly valve

Contact us

RKSfluid Flow Control Company

Web: www.rksfluid.com
Tel:  +86 24 2318 0188
Fax: +86 24 2318 0788
Mail: info@rksfluid.com

Axial Flow Check Valve Low Pressure Drop Blue Epoxy Coated OEM ODM Customized for Water Pump Discharge

  • Valve type: Silent Check Valve
  • Connection: Flange
  • Pressure: PN10-40,Class150-300
  • Body Materials: Ductile iron, Stainless steel
  • Medium: Water, Air
  • Design Standard: GB/T 12235-2007
  • Face to Face: EN 558-1
  • Flange Standard: EN1092-2, ASME B16.5
  • Applications: Water supply systems, Building infrastructure, Fire protection systems, Pump stations
  • Product Details

Non-Slam Check Valve for Water Supply, Pump Stations and Pipeline Protection

RKSfluid Silent Check Valve is designed to prevent reverse flow and help reduce closing impact in water and air pipeline systems. Its compact flanged design is suitable for water supply systems, pump stations, fire protection systems and building infrastructure.

Available in DN50–DN800 with pressure ratings from PN10 to PN40 and Class 150–300, the valve can be configured with ductile iron or stainless steel body materials according to project requirements.



How Does a Silent Check Valve Work?

The valve allows the medium to flow in the required direction while preventing reverse flow when the flow direction changes.

During normal operation, the disc opens under forward flow. When the flow decreases or stops, the disc moves toward the closed position to prevent reverse flow. The silent check design is intended to reduce closing impact and help minimize pressure fluctuations in the pipeline.

This makes it particularly suitable for pump discharge lines and water supply systems where reverse flow protection is important.


Applications

Water Supply Systems
Used in water transmission and distribution pipelines to prevent reverse flow and protect downstream equipment.

Pump Stations
Suitable for pump discharge applications where reverse flow after pump shutdown needs to be controlled.

Fire Protection Systems
Can be used in flanged fire protection pipeline systems where reliable one-way flow is required.

Building Infrastructure
Suitable for water pipeline systems in commercial and industrial buildings.



Request a Quote

Looking for a Silent Check Valve for a water supply system, pump station, fire protection project or building infrastructure?

Send us your DN size, pressure rating, medium, flange standard and quantity. RKSfluid can review your requirements and recommend a suitable valve configuration for your project.

FAQs

A silent check valve is used to prevent reverse flow in pipeline systems while helping reduce valve closing impact. It is commonly applied in water supply, pump stations, fire protection and building infrastructure systems.
The disc is designed to close rapidly as forward flow decreases, helping reduce reverse-flow impact compared with conventional check valve designs. This makes silent check valves suitable for systems where pressure surges need to be controlled.
RKSfluid Silent Check Valves are available from DN50 to DN800, with pressure ratings from PN10 to PN40 and Class 150 to Class 300. The correct rating should be selected according to the system design pressure.
The valve body is available in ductile iron or stainless steel. The disc uses CF8 with EPDM sealing. Material selection should consider the medium, pressure, temperature and project requirements.
The valve is designed according to GB/T 12235-2007. Face-to-face dimensions follow EN 558-1, with flange options including EN 1092-2 and ASME B16.5.
Yes. Silent check valves are commonly used at pump stations and water supply systems to prevent reverse flow and help control pressure fluctuations after pump shutdown.
The valve is suitable for water and air service, with an operating temperature range of 0°C to +80°C. Material and pressure selection should be checked according to the actual operating conditions.
Key factors include pipe diameter, working pressure, medium, temperature, flange standard and installation requirements. For pump applications, flow conditions and potential pressure surges should also be considered during selection.